Native continuum validation boundaries¶
The native tutorial separates implemented capabilities from numerical qualification. The following additional checks belong to the production programme in #1269. They establish agreement for the stated inputs; broader chemical accuracy, basis limits and slab convergence remain separate requirements.
Molecular components¶
Each panel uses iSwiG with 110 nodes per atom and all eleven component
variants in the tutorial: CPCM, COSMO, IEF-PCM, SS(V)PE, D-PCM, original
D-PCM, LPB, SLIC, nonlocal PCM, PV and GOSTSHYP. Dielectric constants are
78.39, LPB kappa is 0.1 inverse bohr, nonlocal parameters are 1.78 and
10 bohr, SLIC parameters are (0.1, 0.2, 0.3), and pressure is 1e-5 atomic
units. The reference uses MOIST commit
922287f53b1cc2ac6b1f77ad6ca4c846d72df7b8 with PySCF 2.6.2 in a separate
environment. Native calculations block imports of MOIST.
Both sides use the same geometry, charge, spin, spherical basis and electronic controls: energy 1e-11 hartree and orbital residual 1e-9, with 200 inner cycles. Native outer convergence additionally requires energy 1e-10 hartree and density and operator residuals below 1e-8. Surface-node enumeration differs first. A verified bijective spatial assignment precedes the potential, charge, energy and AO-operator comparisons.
System and host |
Basis |
Maximum common-density AO-operator error, hartree |
Maximum converged total-energy error, hartree |
Maximum nuclear-gradient error, hartree/bohr |
|---|---|---|---|---|
Ammonium cation, RHF |
def2-SVP |
4.56e-15 |
3.56e-13 |
1.28e-9 |
Acetate anion, RHF |
def2-SVPD |
1.36e-14 |
8.96e-11 |
1.33e-8 |
Methanol, RHF |
def2-SVP |
1.16e-14 |
1.03e-11 |
1.02e-8 |
Acetonitrile, RHF |
def2-SVP |
7.15e-15 |
2.48e-12 |
1.36e-8 |
Benzene, RHF |
def2-SVP |
2.40e-14 |
3.54e-10 |
2.25e-8 |
Water, RKS/PBE0 |
def2-SVP |
4.81e-15 |
3.13e-13 |
Not independently qualified here |
Methanol, RKS/PBE0 |
def2-SVP |
1.17e-14 |
5.39e-12 |
Not independently qualified here |
Acetonitrile, RKS/PBE0 |
def2-SVP |
7.89e-15 |
1.28e-11 |
Not independently qualified here |
Water, RKS/PBE0 |
def2-QZVPD |
9.10e-15 |
6.40e-13 |
Not independently qualified here |
Nuclear entries cover CPCM and GOSTSHYP only. Native gradients rebuild and reconverge every displaced calculation at a 2e-4 bohr central-difference step; the independent RHF reference uses analytic nuclear derivatives. Across the panels the largest native directional density-derivative error at step 1e-5 is 2.29e-10 hartree, and the independent reference maximum is 6.25e-10. Ten trace-preserving directions and the submitted step-size sweeps are retained for each native component. For asymmetric equations the energy derivative is compared independently of apparent charges.
The replacement RKS comparisons supply the exact exported native unpruned
99-by-590 XC quadrature to PySCF and verify its arrays after SCF. Earlier
reference scripts assigned prune=None after the arrays, which resets
PySCF’s grid and caused the reported 1e-7 hartree total-energy differences.
Those matched-grid claims are superseded by the replacement runs. At a
common density, the separately reconstructed PBE0 host energies now agree
within 3.18e-11 hartree for water/SVP and water/TZVPD. No fixed-grid
analytic nuclear derivative is used as a reference for a moving grid.
The water RKS/PBE0 comparison also passes with def2-TZVPD. Its maximum common-density AO-operator and converged total-energy differences are 6.78e-13 and 3.70e-13 hartree. For CPCM and GOSTSHYP, independent reconverged bond differences at 5e-4 bohr agree with the native Cartesian gradient projected on that bond within 5.89e-8 hartree/bohr. The native quadrature is exported separately at each displaced geometry; no fixed-grid analytic RKS gradient is used as that reference. These results extend basis coverage without establishing a basis or surface limit.
The calculations use native builds from
bbafd2379c6a8aa9061eb6dffa3ece2d7c41dc00 or
00371533471f8f6328aa893f3583629d92fb87b3, and the QZVPD panel uses
8f575f34bede2cbcd40b0b655c24a1588a67a998, with the exact loaded Python
module and native-library hashes retained with the issue’s inputs and
results. Later unrelated source changes are not qualified by these runs.
Rigid-motion acceptance remains open in #1289. The original fourteen collected whole-gradient checks have a maximum translation-force sum of 1.32e-8 hartree/bohr. At 110 surface nodes, eight exceed the proposed 1e-6 hartree torque budget; acetate RHF/def2-SVPD with CPCM reaches 4.11e-4 hartree. Independent analytic MOIST gradients reproduce this torque. Agreement between hosts therefore establishes the derivative of the specified discretization while angular convergence remains a separate requirement. Three asymmetric development molecules are undergoing surface and rigid-rotation refinement. No rotationally invariant gradient or geometry-optimization accuracy claim follows from the 110-node panels.
The completed 1454- and 2030-node fixed-density rotation scans for methanol, acetonitrile and acetate still exceed the frozen 1e-6 hartree finite-rotation or torque budget for both CPCM and GOSTSHYP. Refinement is oscillatory. Even acetate/GOSTSHYP at 2030 nodes retains a 3.47e-6 hartree torque and a 3.26e-6 hartree finite-rotation change. Normal completion of these calculations therefore does not close the angular gate. The completed terminal methanol and acetonitrile scans at 5810 nodes pass the finite-rotation budget for both components but still fail the torque budget. Their CPCM angular derivatives reach 4.18e-5 and 1.29e-5 hartree, respectively; GOSTSHYP gives 1.65e-5 and 3.37e-5. Finite-rotation agreement alone therefore does not establish a converged energy derivative. The thresholds and laboratory convention are retained.
An explicitly selected molecule frame is qualified separately in #1292. At 110 and 590 nodes, fixed physical densities for methanol, acetonitrile and acetate with CPCM and GOSTSHYP have maximum finite-rotation change 8.33e-15 hartree and angular derivative 1.38e-11 hartree. The default laboratory-grid failures remain part of #1289.
For water RHF/def2-SVP at 110 nodes, the complete framed CPCM and GOSTSHYP calculations match a pinned upstream calculation in independently constructed canonical coordinates. AO rotations are calibrated from values and overlap matrices. Maximum common-density AO-operator and converged total-energy errors are 5.84e-15 and 3.27e-13 hartree. Pulling back the independent analytic nuclear gradient through the canonical coordinate map agrees with native reconverged differences within 4.74e-9 hartree/bohr; three coordinate-map difference steps are retained. Separate reconverged bond differences at 0.005, 0.002, 0.001 and 0.0005 bohr pass the original nuclear threshold. Native torques are below 5.36e-10 hartree. These checks include frame motion, without projecting a computed gradient. They qualify this finite framed recipe, not a surface or basis limit or a general optimization accuracy claim.
The added 1202-through-5810-node iSwiG rules use all remaining Born widths from the pinned upstream table. All 29 positive-weight rules pass sphere area and volume normalization checks; the 1454-node Born-sphere energy also passes. Complete water RHF/def2-SVP CPCM and COSMO calculations at 1454 nodes agree with the independent host within 2.28e-14 hartree in the common-density AO operator and 2.28e-13 in total energy.
These checks do not establish a surface limit. At a fixed water PBE0/def2-TZVPD density, 590-to-974-node CPCM environment energy changes by 8.04e-6 hartree, while area and volume change by 0.285 and 0.239 percent, exceeding their 0.1 percent budgets. Fully relaxed water PBE0/def2-TZVPD calculations with the 175-by-974 electronic grid also converge both density and environment residuals at 590, 974 and 1454 surface nodes. From 974 to 1454 nodes, CPCM total and environment energies change by 4.26e-6 and 6.12e-6 hartree, respectively; COSMO changes by 4.22e-6 and 6.05e-6. However, area and volume change by 0.241 and 0.191 percent, so this earlier refinement does not pass the complete budget. The subsequent fully relaxed 2030-, 3074- and 5810-node calculations converge both residuals. Both final increments pass the unchanged 1e-5 hartree energy and 0.1 percent area and volume budgets. From 3074 to 5810 nodes, the CPCM total and environment energies change by 1.83e-6 and 2.65e-6 hartree; the COSMO changes are 1.81e-6 and 2.62e-6 hartree. Area and volume change by 0.0444 and 0.0307 percent. These energy and geometry checks do not establish nuclear-gradient grid convergence. The def2-TZVPD-to-QZVPD change also exceeds the proposed basis budget; matching the hosts at QZVPD does not remove that uncertainty. All six relaxed water cases pass independent matched-grid comparisons: the largest AO-operator and total-energy errors are 1.85e-14 and 2.71e-13 hartree, respectively. That agreement qualifies the specified finite discretizations while preserving the failed refinement budgets. The six additional terminal-grid cases also pass the ordered surface, common-density potential, charge, environment-energy, AO-operator and total-energy comparison. Their maximum errors are 2.14e-15 bohr in surface coordinates, 3.07e-14 in surface potential, 9.29e-16 in charges, 5.05e-15 hartree in environment energy, 1.71e-14 hartree in the AO operator and 3.13e-13 hartree in total energy. The first nonzero discrepancy is floating-point surface coordinates after bijective point assignment. Native directional density derivatives differ by at most 9.37e-12 hartree at the 1e-5 step. All twelve water comparisons use the same exported unpruned electronic grid, verified again after the independent SCF; final energy agreement is accompanied by the preceding operator checks.
COSMO-RS numerical checks¶
The full native-only COSMO-RS regression file passes 113 tests, including the two-descriptor thermodynamic chain, COSMOSPACE, activity coefficients, Direct COSMO-RS, nuclear and density derivatives, named-solvent cache identity and unsupported requests. This verifies those defined software contracts, with the experimental and fitted-protocol warnings retained.
A separate implementation of the paper equations reconstructs descriptors, surface-pair statistics, gas dispersion and ring terms, and standard-state conversion for all 16 supported neutral pilot molecules. It imports neither vibe-qc nor MOIST and solves the COSMOSPACE exchange equation with Newton-Krylov iteration. On the archived surfaces its maximum free-energy difference is 3.32e-10 kcal/mol and the maximum infinite-dilution log-activity difference is 5.60e-10. The citations and deliberate printed gas-reference sign corrections follow the thermodynamic design.
All 32 solute and matched-water electronic states pass fresh density, operator, stationarity and energy checks. Three literal cavity rebuilding guards fail at a 1e-12 threshold: their largest coordinate difference is 6.07e-11 bohr. They retain identical node membership and assignment. Separate evaluations on the exact archived surfaces keep the original electronic acceptance criteria; rebuilding changes the environment energy by at most 2.78e-17 hartree and the AO operator by 1.46e-15 hartree. The literal guard failures remain separate evidence.
Fresh-charge thermodynamic scoring and its independent equation check pass for all 16 supported molecules. The largest change from archived free energies is 5.64e-9 kcal/mol. The 13 held-out molecules have signed mean error -1.190640, MAE 1.190640, RMSE 1.279665 and median absolute error 1.137846 kcal/mol. Paired molecule bootstrap with 10000 samples and seed 876 gives descriptive 95 percent intervals of [0.937107, 1.451919] for MAE and [1.017111, 1.522775] for RMSE. Coverage is 16 of 17 selected molecules and 13 of 14 held-out molecules. Fluorobenzene remains unsupported because the published gas-reference parameters lack fluorine. Twelve experimental uncertainty entries are assigned defaults.
Development numerical refinements remain open. This small, nonrandom pilot transfers the published DMol/DNP parameterization to Gaussian BPW91/def2-TZVP surfaces without fitting. The numerical checks do not qualify that transfer as the fitted protocol or establish general experimental hydration accuracy.
The fitted generation recipe also uses the paired-cavity outlying-charge correction of Klamt and Jonas (1996), DOI 10.1063/1.472829, sections III.D and IV, Fig. 1 and Eq. 12. The current native FINE generator does not implement it; #1295 tracks the paired surface, corrected potential, energy and density adjoint. A net screening-charge defect does not measure outlying electron density by itself. Rescaling the net apparent charge cannot replace this local correction. These observations identify a protocol difference; they do not assign the measured hydration bias to it or justify changing fitted parameters on the frozen hold-outs.
Eleven completed development refinements have an additional twenty-two solute and matched-water electronic closure certificates. All pass, including their literal cavity rebuilding guards. Fresh-charge scoring and an independent analytic-Jacobian solution of the COSMOSPACE equation agree within 2.42e-10 kcal/mol in free energy and 4.08e-10 in log activity. The earlier finite-difference Newton-Krylov oracle failures are retained; the replacement changes the independent solver, with the same equations, parameters and acceptance thresholds.
Refining the FINE spacing from 0.20 to 0.15 angstrom changes the methanol, acetonitrile and benzene hydration predictions by -0.0002742, -0.0038111 and -0.0082761 kcal/mol. Increasing the electronic grid from 99-by-974 to 175-by-974 at 0.20 angstrom changes all three predictions by less than 8.08e-8 kcal/mol. However, the acetonitrile and benzene environment energies change by 1.12e-5 and 1.68e-5 hartree under the surface refinement, exceeding the 1e-5 hartree target. Their finer surface controls remain separate. The independently qualified def2-TZVP-to-QZVP controls shift methanol and acetonitrile predictions by +0.137180 and -0.241315 kcal/mol; these measured basis sensitivities preclude a general basis-limit claim. The benzene QZVP control remains pending. The frozen held-out statistics above retain the original 0.25-angstrom protocol.